Raypak Crosswind V Heat Pumps
The TWPH range — 4550, 5550, 6550, 6550EHC, 8550 and 8550EHC. This page is short on purpose: the Crosswind V is a different product from the Crosswind documented alongside it, and its own manual is not among the sources this documentation has verified.
Models in scope
- TWPH 4550
- TWPH 5550
- TWPH 6550 and 6550EHC
- TWPH 8550 and 8550EHC
What applies regardless
A few things are already settled by the rest of the system and by how heat pumps behave, and they can be planned around before the manual is in hand.
- H1, H2, AUX1 and AUX2 are the module's only dry relay contacts, so a dry-contact heat call will consume one of them.
- If it turns out to be a bus device, one device per PORT — every PORT is a single shared channel.
- Expect a compressor restart delay of several minutes and do not retry aggressively into it or report it as a fault.
- The filter pump must keep running while the unit runs and for a period after it stops.
- Decide whether the water setpoint lives in the app or on the unit, and make one follow the other.
Sources
- Raypak, Crosswind Side Discharge Heat Pump Pool Heater Installation & Operation Manual (241827) — automation control two-wire system, terminals 5 and 6, and the time clock override
- iSmart Module relay driver board — KiCad schematic and BOM. H1/H2 and AUX1/AUX2 are optocoupled dry relay contacts; PORT A-D are an unbuffered RS-485 pass-through